Energy Performance Certificate

12 Denbigh Heights, LS9 6RL

EPC Report

Energy rating

Current: 38 F | Potential: 38 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 38 F Potential: 38 F

Environmental impact (CO₂)

Current: 27 | Potential: 27
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 27 Potential: 27
Field Value
LMK KEY 0350-3540-0560-2275-7255
ADDRESS1 12 Denbigh Heights
ADDRESS2
ADDRESS3
POSTCODE LS9 6RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 38
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2025-06-30
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001320
COUNTY
LODGEMENT DATE 2025-06-30
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 27
ENERGY CONSUMPTION CURRENT 626
ENERGY CONSUMPTION POTENTIAL 626
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 7.5
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 88
HEATING COST CURRENT 1312
HEATING COST POTENTIAL 1312
HOT WATER COST CURRENT 1070
HOT WATER COST POTENTIAL 1070
TOTAL FLOOR AREA 71
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Average thermal transmittance 1.65 W/m²K
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 12 Denbigh Heights
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2025-06-30 14:01:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 72238613
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000003
Address display
Nation ew