Energy Performance Certificate

Annex, 3 Minstrel Close, HP1 3RP

EPC Report

Energy rating

Current: 44 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 50 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 80 Potential: 80
Field Value
LMK KEY 0350-2281-6090-2097-3565
ADDRESS1 Annex
ADDRESS2 3 Minstrel Close
ADDRESS3
POSTCODE HP1 3RP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2023-01-19
LOCAL AUTHORITY E07000096
CONSTITUENCY E14001278
COUNTY
LODGEMENT DATE 2023-01-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 581
ENERGY CONSUMPTION POTENTIAL 208
CO2 EMISSIONS CURRENT 2.7
CO2 EMISS CURR PER FLOOR AREA 98
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 32
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 796
HEATING COST POTENTIAL 654
HOT WATER COST CURRENT 336
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 27
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Annex, 3 Minstrel Close
LOCAL AUTHORITY LABEL Dacorum
CONSTITUENCY LABEL Hemel Hempstead
POSTTOWN Hemel Hempstead
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2023-01-20 14:49:23
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100080698926
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew