Energy Performance Certificate

77 Northover, BR1 5JT

EPC Report

Energy rating

Current: 76 C | Potential: 98 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 98 A Potential: 98 A

Environmental impact (CO₂)

Current: 72 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 93 Potential: 93
Field Value
LMK KEY 0350-2244-6260-2597-0771
ADDRESS1 77 Northover
ADDRESS2
ADDRESS3
POSTCODE BR1 5JT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 98
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2023-06-14
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001331
COUNTY
LODGEMENT DATE 2023-06-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 133
ENERGY CONSUMPTION POTENTIAL 11
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 23
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 187
LIGHTING COST POTENTIAL 187
HEATING COST CURRENT 1263
HEATING COST POTENTIAL 1190
HOT WATER COST CURRENT 263
HOT WATER COST POTENTIAL 263
TOTAL FLOOR AREA 143
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77 Northover
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham East
POSTTOWN BROMLEY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-06-15 12:45:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 42
LOW ENERGY FIXED LIGHT COUNT 42
UPRN 100021919852
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew