Energy Performance Certificate

39 MARGARETS WAY, APPLEBY-IN-WESTMORLAND, CA16 6SA

EPC Report

Energy rating

Current: 51 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 43 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 76 Potential: 76
Field Value
LMK KEY 0350-2120-0010-2370-0075
ADDRESS1 39 MARGARETS WAY
ADDRESS2 APPLEBY-IN-WESTMORLAND
ADDRESS3
POSTCODE CA16 6SA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2020-09-30
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001580
COUNTY
LODGEMENT DATE 2020-10-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 300
ENERGY CONSUMPTION POTENTIAL 111
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 78
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 754
HEATING COST POTENTIAL 487
HOT WATER COST CURRENT 214
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 81
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 39 MARGARETS WAY, APPLEBY-IN-WESTMORLAND
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Westmorland and Lonsdale
POSTTOWN APPLEBY-IN-WESTMORLAND
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-10-01 08:39:00
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100110325189
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew