Energy Performance Certificate

537 Shaw Road, Royton, OL2 6PG

EPC Report

Energy rating

Current: 74 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 73 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 90 Potential: 90
Field Value
LMK KEY 0350-2026-4550-2005-0085
ADDRESS1 537 Shaw Road
ADDRESS2 Royton
ADDRESS3
POSTCODE OL2 6PG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-05-06
LOCAL AUTHORITY E08000004
CONSTITUENCY E14001415
COUNTY
LODGEMENT DATE 2025-05-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 186
ENERGY CONSUMPTION POTENTIAL 80
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 609
HEATING COST POTENTIAL 503
HOT WATER COST CURRENT 135
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 76
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 537 Shaw Road, Royton
LOCAL AUTHORITY LABEL Oldham
CONSTITUENCY LABEL Oldham East and Saddleworth
POSTTOWN OLDHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-05-08 12:15:01
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 422000021444
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew