Energy Performance Certificate

29a High Street, Theale, RG7 5AH

EPC Report

Energy rating

Current: 46 E | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 76 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 86 Potential: 86
Field Value
LMK KEY 0350-2017-8640-2626-3111
ADDRESS1 29a High Street
ADDRESS2 Theale
ADDRESS3
POSTCODE RG7 5AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2026-04-23
LOCAL AUTHORITY E06000037
CONSTITUENCY E14001439
COUNTY
LODGEMENT DATE 2026-04-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 239
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 88
LIGHTING COST POTENTIAL 88
HEATING COST CURRENT 3556
HEATING COST POTENTIAL 1800
HOT WATER COST CURRENT 467
HOT WATER COST POTENTIAL 467
TOTAL FLOOR AREA 142
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 79
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial multiple glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 29a High Street, Theale
LOCAL AUTHORITY LABEL West Berkshire
CONSTITUENCY LABEL Reading West and Mid Berkshire
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2026-04-23 17:09:52
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 200002896665
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew