Energy Performance Certificate

7, Honeysuckle Row, Ribbleton, PR2 6YT

EPC Report

Energy rating

Current: 40 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 37 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 74 Potential: 74
Field Value
LMK KEY 0348-9985-7289-1237-1930
ADDRESS1 7, Honeysuckle Row
ADDRESS2 Ribbleton
ADDRESS3
POSTCODE PR2 6YT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-11-04
LOCAL AUTHORITY E07000123
CONSTITUENCY E14001433
COUNTY
LODGEMENT DATE 2013-11-04
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 397
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT
CO2 EMISS CURR PER FLOOR AREA
CO2 EMISSIONS POTENTIAL
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 51
HEATING COST CURRENT 1201
HEATING COST POTENTIAL 639
HOT WATER COST CURRENT 109
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.84
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 7, Honeysuckle Row, Ribbleton
LOCAL AUTHORITY LABEL Preston
CONSTITUENCY LABEL Preston
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-11-04 20:46:20
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100012402851
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew