Energy Performance Certificate

Avoncroft, Offerton, SR4 9JL

EPC Report

Energy rating

Current: 55 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 58 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 64 Potential: 64
Field Value
LMK KEY 0348-8981-6270-6902-5940
ADDRESS1 Avoncroft
ADDRESS2 Offerton
ADDRESS3
POSTCODE SR4 9JL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2012-10-04
LOCAL AUTHORITY E08000024
CONSTITUENCY E14001295
COUNTY
LODGEMENT DATE 2012-10-05
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 238
ENERGY CONSUMPTION POTENTIAL 216
CO2 EMISSIONS CURRENT 6.8
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1410
HEATING COST POTENTIAL 1084
HOT WATER COST CURRENT 209
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 160
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, electric, Air source heat pump, warm air, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Avoncroft, Offerton
LOCAL AUTHORITY LABEL Sunderland
CONSTITUENCY LABEL Houghton and Sunderland South
POSTTOWN SUNDERLAND
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2012-10-05 12:26:30
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 32
UPRN 45001850
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000001
Address display
Nation ew