Energy Performance Certificate

Flat 35 Garrison Heights, 55, Henry Darlot Drive, NW7 1RF

EPC Report

Energy rating

Current: 87 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 93 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 Current: 93 93 Potential: 93
Field Value
LMK KEY 0348-3944-7372-5953-3904
ADDRESS1 Flat 35 Garrison Heights
ADDRESS2 55, Henry Darlot Drive
ADDRESS3
POSTCODE NW7 1RF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Maisonette
BUILT FORM Detached
INSPECTION DATE 2017-12-04
LOCAL AUTHORITY E09000003
CONSTITUENCY E14001169
COUNTY
LODGEMENT DATE 2017-12-04
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 93
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 36
ENERGY CONSUMPTION POTENTIAL 36
CO2 EMISSIONS CURRENT 1.0
CO2 EMISS CURR PER FLOOR AREA 7
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 274
HEATING COST POTENTIAL 274
HOT WATER COST CURRENT 102
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 147
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and at least two room thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.16 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and at least two room thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.14
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 35 Garrison Heights, 55, Henry Darlot Drive
LOCAL AUTHORITY LABEL Barnet
CONSTITUENCY LABEL Chipping Barnet
POSTTOWN LONDON
CONSTRUCTION AGE BAND 2015
LODGEMENT DATETIME 2017-12-04 08:36:08
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 1
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10093299258
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew