Energy Performance Certificate

33, Novers Road, BS4 1QY

EPC Report

Energy rating

Current: 54 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 48 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 84 Potential: 84
Field Value
LMK KEY 0348-3042-7228-2064-2914
ADDRESS1 33, Novers Road
ADDRESS2
ADDRESS3
POSTCODE BS4 1QY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-08-04
LOCAL AUTHORITY E06000023
CONSTITUENCY E14001135
COUNTY
LODGEMENT DATE 2014-08-04
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 273
ENERGY CONSUMPTION POTENTIAL 70
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 868
HEATING COST POTENTIAL 484
HOT WATER COST CURRENT 285
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 102
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 25 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Novers Road
LOCAL AUTHORITY LABEL Bristol, City of
CONSTITUENCY LABEL Bristol South
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-08-04 14:52:36
TENURE Rented (social)
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 146406
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew