Energy Performance Certificate

8, Arncliffe Road, Heysham, LA3 2AT

EPC Report

Energy rating

Current: 20 G | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 24 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 77 Potential: 77
Field Value
LMK KEY 0348-2038-7286-0697-1910
ADDRESS1 8, Arncliffe Road
ADDRESS2 Heysham
ADDRESS3
POSTCODE LA3 2AT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2013-06-04
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001372
COUNTY
LODGEMENT DATE 2013-06-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 670
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 127
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 1006
HEATING COST POTENTIAL 510
HOT WATER COST CURRENT 418
HOT WATER COST POTENTIAL 53
TOTAL FLOOR AREA 55
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Arncliffe Road, Heysham
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Morecambe and Lunesdale
POSTTOWN MORECAMBE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-06-05 10:04:30
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100010479864
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew