Energy Performance Certificate

Amroth House, Harkstead Road, Holbrook, IP9 2RA

EPC Report

Energy rating

Current: 18 G | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 G Current: 18 G 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 1 | Potential: 48
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 48 Potential: 48
Field Value
LMK KEY 0347-2825-7423-9596-1575
ADDRESS1 Amroth House
ADDRESS2 Harkstead Road
ADDRESS3 Holbrook
POSTCODE IP9 2RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 18
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-02-15
LOCAL AUTHORITY E07000200
CONSTITUENCY E14001494
COUNTY
LODGEMENT DATE 2016-02-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 48
ENERGY CONSUMPTION CURRENT 972
ENERGY CONSUMPTION POTENTIAL 295
CO2 EMISSIONS CURRENT 17.3
CO2 EMISS CURR PER FLOOR AREA 171
CO2 EMISSIONS POTENTIAL 5.3
LIGHTING COST CURRENT 125
LIGHTING COST POTENTIAL 70
HEATING COST CURRENT 2290
HEATING COST POTENTIAL 1039
HOT WATER COST CURRENT 216
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 101
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Amroth House, Harkstead Road, Holbrook
LOCAL AUTHORITY LABEL Babergh
CONSTITUENCY LABEL South Suffolk
POSTTOWN IPSWICH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-02-15 15:56:31
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100091363555
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display
Nation ew