13, Palmerston Road, Garston, L19 1RN

EPC Report

Energy rating

Current: 35 F | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 31 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 69 Potential: 69
Field Value
LMK KEY 0345-2836-7571-9396-2365
ADDRESS1 13, Palmerston Road
ADDRESS2 Garston
ADDRESS3
POSTCODE L19 1RN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-03-16
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001337
COUNTY
LODGEMENT DATE 2016-03-16
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 449
ENERGY CONSUMPTION POTENTIAL 171
CO2 EMISSIONS CURRENT 9.6
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 3.7
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 85
HEATING COST CURRENT 1946
HEATING COST POTENTIAL 989
HOT WATER COST CURRENT 132
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 122
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS 13, Palmerston Road, Garston
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Garston
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-03-16 15:59:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 38115196
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display