Energy Performance Certificate

5, Orchard Close, Sunniside, NE16 5NB

EPC Report

Energy rating

Current: 46 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 45 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 88 Potential: 88
Field Value
LMK KEY 0344-2828-6350-9104-9075
ADDRESS1 5, Orchard Close
ADDRESS2 Sunniside
ADDRESS3
POSTCODE NE16 5NB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-05-08
LOCAL AUTHORITY E08000037
CONSTITUENCY E14001244
COUNTY
LODGEMENT DATE 2014-05-08
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 407
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 42
HEATING COST CURRENT 909
HEATING COST POTENTIAL 441
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Orchard Close, Sunniside
LOCAL AUTHORITY LABEL Gateshead
CONSTITUENCY LABEL Gateshead Central and Whickham
POSTTOWN NEWCASTLE UPON TYNE
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2014-05-08 19:44:26
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10022991322
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew