Energy Performance Certificate

10 Southview House, 19a Queen Elizabeth Street, SE1 2LP

EPC Report

Energy rating

Current: 87 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 B Current: 87 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 88 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 88 Potential: 88
Field Value
LMK KEY 0340-3668-1010-2307-0645
ADDRESS1 10 Southview House
ADDRESS2 19a Queen Elizabeth Street
ADDRESS3
POSTCODE SE1 2LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 87
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2023-09-08
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001085
COUNTY
LODGEMENT DATE 2023-09-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 54
ENERGY CONSUMPTION POTENTIAL 54
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 224
LIGHTING COST POTENTIAL 224
HEATING COST CURRENT 564
HEATING COST POTENTIAL 564
HOT WATER COST CURRENT 544
HOT WATER COST POTENTIAL 544
TOTAL FLOOR AREA 217
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.18 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 10 Southview House, 19a Queen Elizabeth Street
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Bermondsey and Old Southwark
POSTTOWN London
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2023-09-08 09:08:07
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 36
LOW ENERGY FIXED LIGHT COUNT 36
UPRN 10096873997
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display