Energy Performance Certificate
Flat 42, Regal House, Lensbury Avenue, SW6 2GZ
Energy rating
Current: 71 C | Potential: 71 C
Environmental impact (CO₂)
Current: 52
| Potential: 52
| Field | Value |
|---|---|
| LMK KEY | 0340-3022-9209-3677-8204 |
| ADDRESS1 | Flat 42 |
| ADDRESS2 | Regal House |
| ADDRESS3 | Lensbury Avenue |
| POSTCODE | SW6 2GZ |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 71 |
| POTENTIAL ENERGY EFFICIENCY | 71 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2023-01-04 |
| LOCAL AUTHORITY | E09000013 |
| CONSTITUENCY | E14001160 |
| COUNTY | — |
| LODGEMENT DATE | 2023-01-04 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 52 |
| ENVIRONMENT IMPACT POTENTIAL | 52 |
| ENERGY CONSUMPTION CURRENT | 179 |
| ENERGY CONSUMPTION POTENTIAL | 179 |
| CO2 EMISSIONS CURRENT | 15 |
| CO2 EMISS CURR PER FLOOR AREA | 30 |
| CO2 EMISSIONS POTENTIAL | 15 |
| LIGHTING COST CURRENT | 232 |
| LIGHTING COST POTENTIAL | 232 |
| HEATING COST CURRENT | 2976 |
| HEATING COST POTENTIAL | 2976 |
| HOT WATER COST CURRENT | 360 |
| HOT WATER COST POTENTIAL | 360 |
| TOTAL FLOOR AREA | 493 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 3 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | triple glazing |
| GLAZED AREA | More Than Typical |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 10 |
| NUMBER HEATED ROOMS | 10 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric instantaneous at point of use |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully triple glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | System built, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Flat, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Electric underfloor heating |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | no corridor |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.84 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Flat 42, Regal House, Lensbury Avenue |
| LOCAL AUTHORITY LABEL | Hammersmith and Fulham |
| CONSTITUENCY LABEL | Chelsea and Fulham |
| POSTTOWN | LONDON |
| CONSTRUCTION AGE BAND | England and Wales: 2003-2006 |
| LODGEMENT DATETIME | 2023-01-04 22:52:54 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 145 |
| LOW ENERGY FIXED LIGHT COUNT | 145 |
| UPRN | 34140960 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2023.csv |
| COUNTRY | England |
| REGION | E12000007 |
| Address display | — |
| Nation | ew |