Energy Performance Certificate

17 Park Court, Ilkeston Road, DE75 7DS

EPC Report

Energy rating

Current: 69 C | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 88 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 89 Potential: 89
Field Value
LMK KEY 0340-2906-6550-2296-8265
ADDRESS1 17 Park Court
ADDRESS2 Ilkeston Road
ADDRESS3
POSTCODE DE75 7DS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Maisonette
BUILT FORM Not Recorded
INSPECTION DATE 2026-05-16
LOCAL AUTHORITY E07000032
CONSTITUENCY E14001066
COUNTY
LODGEMENT DATE 2026-05-17
TRANSACTION TYPE Stock condition survey
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 174
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 16
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 796
HEATING COST POTENTIAL 658
HOT WATER COST CURRENT 376
HOT WATER COST POTENTIAL 376
TOTAL FLOOR AREA 54
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Controls for high heat retention storage heaters
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Controls for high heat retention storage heaters
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical extract, decentralised (MEV dc)
ADDRESS 17 Park Court, Ilkeston Road
LOCAL AUTHORITY LABEL Amber Valley
CONSTITUENCY LABEL Amber Valley
POSTTOWN HEANOR
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2026-05-17 20:42:13
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200000387946
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000004
Address display
Nation ew