Energy Performance Certificate

10, The Crescent, BA13 3HE

EPC Report

Energy rating

Current: 72 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 73 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 84 Potential: 84
Field Value
LMK KEY 0340-2889-6039-9074-7851
ADDRESS1 10, The Crescent
ADDRESS2
ADDRESS3
POSTCODE BA13 3HE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-07-31
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001498
COUNTY
LODGEMENT DATE 2014-07-31
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 146
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 652
HEATING COST POTENTIAL 601
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 121
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, The Crescent
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South West Wiltshire
POSTTOWN WESTBURY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-07-31 13:20:51
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 18
UPRN 100121108164
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display
Nation ew