Energy Performance Certificate

17 Hardwick Crescent, Syston, LE7 1NY

EPC Report

Energy rating

Current: 58 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 52 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 88 Potential: 88
Field Value
LMK KEY 0340-2749-9150-2872-6675
ADDRESS1 17 Hardwick Crescent
ADDRESS2 Syston
ADDRESS3
POSTCODE LE7 1NY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-05-31
LOCAL AUTHORITY E07000130
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2022-05-31
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 349
ENERGY CONSUMPTION POTENTIAL 82
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 62
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 592
HEATING COST POTENTIAL 335
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 62
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17 Hardwick Crescent, Syston
LOCAL AUTHORITY LABEL Charnwood
CONSTITUENCY LABEL Melton and Syston
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-05-31 08:52:28
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100030417693
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew