Energy Performance Certificate

62 Henshall Road, Bollington, SK10 5DN

EPC Report

Energy rating

Current: 62 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 52 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 67 Potential: 67
Field Value
LMK KEY 0340-2586-0480-2304-7055
ADDRESS1 62 Henshall Road
ADDRESS2 Bollington
ADDRESS3
POSTCODE SK10 5DN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-08-06
LOCAL AUTHORITY E06000049
CONSTITUENCY E14001347
COUNTY
LODGEMENT DATE 2024-08-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 240
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 6.5
LIGHTING COST CURRENT 200
LIGHTING COST POTENTIAL 200
HEATING COST CURRENT 3199
HEATING COST POTENTIAL 2377
HOT WATER COST CURRENT 201
HOT WATER COST POTENTIAL 201
TOTAL FLOOR AREA 224
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.15
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 62 Henshall Road, Bollington
LOCAL AUTHORITY LABEL Cheshire East
CONSTITUENCY LABEL Macclesfield
POSTTOWN MACCLESFIELD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-08-06 15:51:45
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 45
LOW ENERGY FIXED LIGHT COUNT 40
UPRN 100010148413
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000002
Address display