Energy Performance Certificate

33 Charnwood, Ratby, LE6 0LD

EPC Report

Energy rating

Current: 28 F | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 76 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 71 Potential: 71
Field Value
LMK KEY 0340-2252-1510-2805-2441
ADDRESS1 33 Charnwood
ADDRESS2 Ratby
ADDRESS3
POSTCODE LE6 0LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2025-09-02
LOCAL AUTHORITY E07000132
CONSTITUENCY E14001364
COUNTY
LODGEMENT DATE 2025-09-20
TRANSACTION TYPE Grant scheme
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 238
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 3174
HEATING COST POTENTIAL 1171
HOT WATER COST CURRENT 204
HOT WATER COST POTENTIAL 169
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Good lighting efficiency
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical ventilation without heat recovery (MV)
ADDRESS 33 Charnwood, Ratby
LOCAL AUTHORITY LABEL Hinckley and Bosworth
CONSTITUENCY LABEL Mid Leicestershire
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-09-20 14:05:09
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 31
LOW ENERGY FIXED LIGHT COUNT 31
UPRN 100030516113
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000004
Address display
Nation ew