Energy Performance Certificate

12 Heronsgate, CO13 0AW

EPC Report

Energy rating

Current: 57 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 48 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 73 Potential: 73
Field Value
LMK KEY 0340-2180-8140-2522-3571
ADDRESS1 12 Heronsgate
ADDRESS2
ADDRESS3
POSTCODE CO13 0AW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-04-20
LOCAL AUTHORITY E07000076
CONSTITUENCY E14001174
COUNTY
LODGEMENT DATE 2022-04-20
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 294
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 6.6
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 101
HEATING COST CURRENT 973
HEATING COST POTENTIAL 695
HOT WATER COST CURRENT 211
HOT WATER COST POTENTIAL 90
TOTAL FLOOR AREA 126
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12 Heronsgate
LOCAL AUTHORITY LABEL Tendring
CONSTITUENCY LABEL Clacton
POSTTOWN FRINTON-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2022-04-20 20:51:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100090628107
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000006
Address display
Nation ew