Energy Performance Certificate

111 Coniston Road, WV6 9DT

EPC Report

Energy rating

Current: 41 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 36 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 75 Potential: 75
Field Value
LMK KEY 0336-3017-3206-5202-1204
ADDRESS1 111 Coniston Road
ADDRESS2
ADDRESS3
POSTCODE WV6 9DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2022-06-07
LOCAL AUTHORITY E08000031
CONSTITUENCY E14001596
COUNTY
LODGEMENT DATE 2022-06-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 405
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 9.0
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 1350
HEATING COST POTENTIAL 664
HOT WATER COST CURRENT 490
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 127
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 85
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 111 Coniston Road
LOCAL AUTHORITY LABEL Wolverhampton
CONSTITUENCY LABEL Wolverhampton West
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2022-06-09 16:07:18
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100071148865
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000005
Address display
Nation ew