Energy Performance Certificate

Rabec, Sandhutton, YO7 4RW

EPC Report

Energy rating

Current: 50 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 42 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 79 Potential: 79
Field Value
LMK KEY 0332-3023-5202-1897-8204
ADDRESS1 Rabec
ADDRESS2 Sandhutton
ADDRESS3
POSTCODE YO7 4RW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-02-07
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001544
COUNTY
LODGEMENT DATE 2023-02-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 390
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 901
HEATING COST POTENTIAL 494
HOT WATER COST CURRENT 371
HOT WATER COST POTENTIAL 159
TOTAL FLOOR AREA 60
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Rabec, Sandhutton
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Thirsk and Malton
POSTTOWN THIRSK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2023-02-07 23:43:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 200003302368
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000003
Address display
Nation ew