Energy Performance Certificate

Hill Valley, Edginswell Lane, TQ2 7JF

EPC Report

Energy rating

Current: 99 A | Potential: 99 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 99 A Current: 99 A 99 A Potential: 99 A

Environmental impact (CO₂)

Current: 93 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 93 Current: 93 93 Potential: 93
Field Value
LMK KEY 0330-3477-9290-2104-0981
ADDRESS1 Hill Valley
ADDRESS2 Edginswell Lane
ADDRESS3
POSTCODE TQ2 7JF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 99
POTENTIAL ENERGY EFFICIENCY 99
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-01-03
LOCAL AUTHORITY E06000027
CONSTITUENCY E14001551
COUNTY
LODGEMENT DATE 2024-01-03
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 93
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT -27
ENERGY CONSUMPTION POTENTIAL -27
CO2 EMISSIONS CURRENT 0.3
CO2 EMISS CURR PER FLOOR AREA 0.9
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 350
LIGHTING COST POTENTIAL 350
HEATING COST CURRENT 1204
HEATING COST POTENTIAL 1204
HOT WATER COST CURRENT 197
HOT WATER COST POTENTIAL 197
TOTAL FLOOR AREA 381
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.16 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.08 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Oil: heating oil
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Hill Valley, Edginswell Lane
LOCAL AUTHORITY LABEL Torbay
CONSTITUENCY LABEL Torbay
POSTTOWN TORQUAY
CONSTRUCTION AGE BAND 2022
LODGEMENT DATETIME 2024-01-03 10:01:17
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 50
LOW ENERGY FIXED LIGHT COUNT 50
UPRN 10094528209
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew