Energy Performance Certificate
80 Southwell Road, PE13 3LQ
Energy rating
Current: 74 C | Potential: 74 C
Environmental impact (CO₂)
Current: 74
| Potential: 74
| Field | Value |
|---|---|
| LMK KEY | 0330-3072-8290-2004-8285 |
| ADDRESS1 | 80 Southwell Road |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | PE13 3LQ |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 74 |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2024-01-02 |
| LOCAL AUTHORITY | E07000010 |
| CONSTITUENCY | E14001390 |
| COUNTY | — |
| LODGEMENT DATE | 2024-01-02 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 74 |
| ENVIRONMENT IMPACT POTENTIAL | 74 |
| ENERGY CONSUMPTION CURRENT | 174 |
| ENERGY CONSUMPTION POTENTIAL | 174 |
| CO2 EMISSIONS CURRENT | 2.2 |
| CO2 EMISS CURR PER FLOOR AREA | 31 |
| CO2 EMISSIONS POTENTIAL | 2.2 |
| LIGHTING COST CURRENT | 159 |
| LIGHTING COST POTENTIAL | 159 |
| HEATING COST CURRENT | 826 |
| HEATING COST POTENTIAL | 826 |
| HOT WATER COST CURRENT | 224 |
| HOT WATER COST POTENTIAL | 224 |
| TOTAL FLOOR AREA | 71 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 70 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.70 W/m²K |
| FLOOR ENERGY EFF | Poor |
| FLOOR ENV EFF | Poor |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.37 W/m²K |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.14 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 70% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Gas: mains gas |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.43 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | 80 Southwell Road |
| LOCAL AUTHORITY LABEL | Fenland |
| CONSTITUENCY LABEL | North East Cambridgeshire |
| POSTTOWN | WISBECH |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2024-01-02 10:12:37 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| UPRN | 100090084977 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2024.csv |
| COUNTRY | England |
| REGION | E12000006 |
| Address display | — |
| Nation | ew |