Energy Performance Certificate

8 Millday Close, Kibworth Harcourt, LE8 0RY

EPC Report

Energy rating

Current: 82 B | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 79 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 83 Potential: 83
Field Value
LMK KEY 0330-2575-0130-2392-2821
ADDRESS1 8 Millday Close
ADDRESS2 Kibworth Harcourt
ADDRESS3
POSTCODE LE8 0RY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2022-07-15
LOCAL AUTHORITY E07000131
CONSTITUENCY E14001266
COUNTY
LODGEMENT DATE 2022-07-16
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 101
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 144
HEATING COST CURRENT 641
HEATING COST POTENTIAL 641
HOT WATER COST CURRENT 108
HOT WATER COST POTENTIAL 108
TOTAL FLOOR AREA 231
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.28
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8 Millday Close, Kibworth Harcourt
LOCAL AUTHORITY LABEL Harborough
CONSTITUENCY LABEL Harborough, Oadby and Wigston
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2022-07-16 14:04:25
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 41
LOW ENERGY FIXED LIGHT COUNT 41
UPRN 10034458589
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew