Energy Performance Certificate

187 Tollgate Road, E6 5JY

EPC Report

Energy rating

Current: 76 C | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 52 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 75 Potential: 75
Field Value
LMK KEY 0330-2444-5280-2307-4035
ADDRESS1 187 Tollgate Road
ADDRESS2
ADDRESS3
POSTCODE E6 5JY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-08-04
LOCAL AUTHORITY E09000025
CONSTITUENCY E14001576
COUNTY
LODGEMENT DATE 2023-08-06
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 253
ENERGY CONSUMPTION POTENTIAL 113
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 169
LIGHTING COST POTENTIAL 169
HEATING COST CURRENT 1259
HEATING COST POTENTIAL 690
HOT WATER COST CURRENT 496
HOT WATER COST POTENTIAL 203
TOTAL FLOOR AREA 88
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 75
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 187 Tollgate Road
LOCAL AUTHORITY LABEL Newham
CONSTITUENCY LABEL West Ham and Beckton
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2023-08-06 06:40:33
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 46074608
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew