Energy Performance Certificate

22 Effingham Street, CT11 9AT

EPC Report

Energy rating

Current: 1 G | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 5 | Potential: 36
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 5 Current: 5 36 Potential: 36
Field Value
LMK KEY 0330-2355-1340-2324-6785
ADDRESS1 22 Effingham Street
ADDRESS2
ADDRESS3
POSTCODE CT11 9AT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2024-04-25
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001216
COUNTY
LODGEMENT DATE 2024-05-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 5
ENVIRONMENT IMPACT POTENTIAL 36
ENERGY CONSUMPTION CURRENT 904
ENERGY CONSUMPTION POTENTIAL 415
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 153
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 198
LIGHTING COST POTENTIAL 239
HEATING COST CURRENT 7620
HEATING COST POTENTIAL 2153
HOT WATER COST CURRENT 423
HOT WATER COST POTENTIAL 223
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Less Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 36
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 36% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22 Effingham Street
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL East Thanet
POSTTOWN RAMSGATE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-05-30 17:37:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100061135807
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000008
Address display
Nation ew