Energy Performance Certificate

Park View, The Parade, St. Mary's, TR21 0LP

EPC Report

Energy rating

Current: 55 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 51 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 64 Potential: 64
Field Value
LMK KEY 0330-2351-4350-2007-4871
ADDRESS1 Park View
ADDRESS2 The Parade
ADDRESS3 St. Mary's
POSTCODE TR21 0LP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-05-09
LOCAL AUTHORITY E06000053
CONSTITUENCY E14001511
COUNTY
LODGEMENT DATE 2024-05-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 208
ENERGY CONSUMPTION POTENTIAL 137
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 35
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 201
LIGHTING COST POTENTIAL 218
HEATING COST CURRENT 2705
HEATING COST POTENTIAL 1469
HOT WATER COST CURRENT 343
HOT WATER COST POTENTIAL 228
TOTAL FLOOR AREA 190
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Park View, The Parade, St. Mary's
LOCAL AUTHORITY LABEL Isles of Scilly
CONSTITUENCY LABEL St Ives
POSTTOWN ISLES OF SCILLY
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-05-16 09:17:59
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 192000814
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000009
Address display
Nation ew