Energy Performance Certificate

54 HANBURY GARDENS, HIGHWOODS, CO4 9TS

EPC Report

Energy rating

Current: 70 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 54 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 64 Potential: 64
Field Value
LMK KEY 0330-2249-7060-2099-2735
ADDRESS1 54 HANBURY GARDENS
ADDRESS2 HIGHWOODS
ADDRESS3
POSTCODE CO4 9TS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2021-06-11
LOCAL AUTHORITY E07000071
CONSTITUENCY E14001176
COUNTY
LODGEMENT DATE 2021-06-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 420
ENERGY CONSUMPTION POTENTIAL 331
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 378
HEATING COST POTENTIAL 240
HOT WATER COST CURRENT 161
HOT WATER COST POTENTIAL 161
TOTAL FLOOR AREA 39
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.31
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 54 HANBURY GARDENS, HIGHWOODS
LOCAL AUTHORITY LABEL Colchester
CONSTITUENCY LABEL Colchester
POSTTOWN COLCHESTER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2021-06-11 14:03:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090455266
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000006
Address display
Nation ew