Energy Performance Certificate
11 Fairway Lakes Village, Caldecott Hall, Fritton, NR31 9EY
Energy rating
Current: 63 D | Potential: 74 C
Environmental impact (CO₂)
Current: 75
| Potential: 84
| Field | Value |
|---|---|
| LMK KEY | 0330-2146-4550-2005-6085 |
| ADDRESS1 | 11 Fairway Lakes Village |
| ADDRESS2 | Caldecott Hall |
| ADDRESS3 | Fritton |
| POSTCODE | NR31 9EY |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 63 |
| POTENTIAL ENERGY EFFICIENCY | 74 |
| PROPERTY TYPE | House |
| BUILT FORM | Detached |
| INSPECTION DATE | 2025-05-06 |
| LOCAL AUTHORITY | E07000145 |
| CONSTITUENCY | E14001256 |
| COUNTY | — |
| LODGEMENT DATE | 2025-05-06 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 75 |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| ENERGY CONSUMPTION CURRENT | 119 |
| ENERGY CONSUMPTION POTENTIAL | 61 |
| CO2 EMISSIONS CURRENT | 3.1 |
| CO2 EMISS CURR PER FLOOR AREA | 25 |
| CO2 EMISSIONS POTENTIAL | 1.8 |
| LIGHTING COST CURRENT | 136 |
| LIGHTING COST POTENTIAL | 136 |
| HEATING COST CURRENT | 956 |
| HEATING COST POTENTIAL | 956 |
| HOT WATER COST CURRENT | 256 |
| HOT WATER COST POTENTIAL | 167 |
| TOTAL FLOOR AREA | 121 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | triple glazing |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| NUMBER HEATED ROOMS | 4 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully triple glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and underfloor heating, LPG |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | LPG (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.15 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 11 Fairway Lakes Village, Caldecott Hall, Fritton |
| LOCAL AUTHORITY LABEL | Great Yarmouth |
| CONSTITUENCY LABEL | Great Yarmouth |
| POSTTOWN | GREAT YARMOUTH |
| CONSTRUCTION AGE BAND | England and Wales: 2003-2006 |
| LODGEMENT DATETIME | 2025-05-06 17:53:03 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 10 |
| UPRN | 10023460280 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2025.csv |
| COUNTRY | England |
| REGION | E12000006 |
| Address display | — |
| Nation | ew |