Energy Performance Certificate

58 Spring Vale, PO8 9DB

EPC Report

Energy rating

Current: 64 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 58 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 Current: 58 67 Potential: 67
Field Value
LMK KEY 0330-2011-5660-2796-8365
ADDRESS1 58 Spring Vale
ADDRESS2
ADDRESS3
POSTCODE PO8 9DB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2026-06-19
LOCAL AUTHORITY E07000085
CONSTITUENCY E14001214
COUNTY
LODGEMENT DATE 2026-06-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 58
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 208
ENERGY CONSUMPTION POTENTIAL 158
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1463
HEATING COST POTENTIAL 1173
HOT WATER COST CURRENT 221
HOT WATER COST POTENTIAL 221
TOTAL FLOOR AREA 116
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 58 Spring Vale
LOCAL AUTHORITY LABEL East Hampshire
CONSTITUENCY LABEL East Hampshire
POSTTOWN WATERLOOVILLE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2026-06-19 14:15:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 32
UPRN 100060291038
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000008
Address display
Nation ew