Energy Performance Certificate

75, Apollo Walk, HU8 0TT

EPC Report

Energy rating

Current: 32 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 39 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 86 Potential: 86
Field Value
LMK KEY 0329-2831-7654-9394-5275
ADDRESS1 75, Apollo Walk
ADDRESS2
ADDRESS3
POSTCODE HU8 0TT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-05-19
LOCAL AUTHORITY E06000010
CONSTITUENCY E14001313
COUNTY
LODGEMENT DATE 2014-05-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 430
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 6.2
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 91
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 1448
HEATING COST POTENTIAL 453
HOT WATER COST CURRENT 90
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 79
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 75, Apollo Walk
LOCAL AUTHORITY LABEL Kingston upon Hull, City of
CONSTITUENCY LABEL Kingston upon Hull East
POSTTOWN HULL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-05-19 09:54:11
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 21006234
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew