Energy Performance Certificate
Flat 3 The Villa, 23, Old Road, Mottram, SK14 6LG
Energy rating
Current: 30 F | Potential: 76 C
Environmental impact (CO₂)
Current: 17
| Potential: 59
| Field | Value |
|---|---|
| LMK KEY | 0328-9921-6239-7428-6980 |
| ADDRESS1 | Flat 3 The Villa |
| ADDRESS2 | 23, Old Road |
| ADDRESS3 | Mottram |
| POSTCODE | SK14 6LG |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 30 |
| POTENTIAL ENERGY EFFICIENCY | 76 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2018-11-02 |
| LOCAL AUTHORITY | E08000008 |
| CONSTITUENCY | E14001515 |
| COUNTY | — |
| LODGEMENT DATE | 2018-11-02 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 17 |
| ENVIRONMENT IMPACT POTENTIAL | 59 |
| ENERGY CONSUMPTION CURRENT | 953 |
| ENERGY CONSUMPTION POTENTIAL | 348 |
| CO2 EMISSIONS CURRENT | 8.3 |
| CO2 EMISS CURR PER FLOOR AREA | 161 |
| CO2 EMISSIONS POTENTIAL | 3.0 |
| LIGHTING COST CURRENT | 74 |
| LIGHTING COST POTENTIAL | 44 |
| HEATING COST CURRENT | 1300 |
| HEATING COST POTENTIAL | 341 |
| HOT WATER COST CURRENT | 266 |
| HOT WATER COST POTENTIAL | 144 |
| TOTAL FLOOR AREA | 52 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 3 |
| FLAT TOP STOREY | Y |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Manual charge control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 2 |
| NUMBER HEATED ROOMS | 2 |
| LOW ENERGY LIGHTING | 33 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 50 mm loft insulation |
| ROOF ENERGY EFF | Poor |
| ROOF ENV EFF | Poor |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 33% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | unheated corridor |
| UNHEATED CORRIDOR LENGTH | 2.62 |
| FLOOR HEIGHT | 2.56 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | Flat 3 The Villa, 23, Old Road, Mottram |
| LOCAL AUTHORITY LABEL | Tameside |
| CONSTITUENCY LABEL | Stalybridge and Hyde |
| POSTTOWN | HYDE |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2018-11-02 18:45:55 |
| TENURE | rented (private) |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| UPRN | 10014258723 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2018.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |