Energy Performance Certificate

62 Coronation Avenue, Cuffley, EN6 4FH

EPC Report

Energy rating

Current: 94 A | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 92 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 Current: 92 92 Potential: 92
Field Value
LMK KEY 0320-3352-8450-2895-6331
ADDRESS1 62 Coronation Avenue
ADDRESS2 Cuffley
ADDRESS3
POSTCODE EN6 4FH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-05-12
LOCAL AUTHORITY E07000241
CONSTITUENCY E14001284
COUNTY
LODGEMENT DATE 2025-05-12
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 92
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 46
ENERGY CONSUMPTION POTENTIAL 46
CO2 EMISSIONS CURRENT 0.8
CO2 EMISS CURR PER FLOOR AREA 8.9
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 272
HEATING COST POTENTIAL 272
HOT WATER COST CURRENT 148
HOT WATER COST POTENTIAL 148
TOTAL FLOOR AREA 94
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.12 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.09 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Excelent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 62 Coronation Avenue, Cuffley
LOCAL AUTHORITY LABEL Welwyn Hatfield
CONSTITUENCY LABEL Hertsmere
POSTTOWN POTTERS BAR
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2025-05-12 07:47:02
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 10095912319
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000006
Address display
Nation ew