Energy Performance Certificate

14 Talbot Road, BH9 2JF

EPC Report

Energy rating

Current: 21 F | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 16 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 16 Current: 16 72 Potential: 72
Field Value
LMK KEY 0320-2882-9260-2827-3701
ADDRESS1 14 Talbot Road
ADDRESS2
ADDRESS3
POSTCODE BH9 2JF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2023-06-22
LOCAL AUTHORITY E06000058
CONSTITUENCY E14001116
COUNTY
LODGEMENT DATE 2023-06-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 16
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 565
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 407
LIGHTING COST POTENTIAL 207
HEATING COST CURRENT 7298
HEATING COST POTENTIAL 1935
HOT WATER COST CURRENT 260
HOT WATER COST POTENTIAL 264
TOTAL FLOOR AREA 171
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.89
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14 Talbot Road
LOCAL AUTHORITY LABEL Bournemouth, Christchurch and Poole
CONSTITUENCY LABEL Bournemouth West
POSTTOWN BOURNEMOUTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2023-06-22 15:15:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100041113257
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew