Energy Performance Certificate

1 Townsend, Barford St. Michael, OX15 0RE

EPC Report

Energy rating

Current: 27 F | Potential: 53 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 53 E Potential: 53 E

Environmental impact (CO₂)

Current: 41 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 62 Potential: 62
Field Value
LMK KEY 0320-2872-1490-2925-0575
ADDRESS1 1 Townsend
ADDRESS2 Barford St. Michael
ADDRESS3
POSTCODE OX15 0RE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 53
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2025-01-22
LOCAL AUTHORITY E07000177
CONSTITUENCY E14001072
COUNTY
LODGEMENT DATE 2025-01-24
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 382
ENERGY CONSUMPTION POTENTIAL 229
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 140
LIGHTING COST POTENTIAL 140
HEATING COST CURRENT 5065
HEATING COST POTENTIAL 3287
HOT WATER COST CURRENT 729
HOT WATER COST POTENTIAL 290
TOTAL FLOOR AREA 182
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.58
PHOTO SUPPLY 15
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Townsend, Barford St. Michael
LOCAL AUTHORITY LABEL Cherwell
CONSTITUENCY LABEL Banbury
POSTTOWN BANBURY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2025-01-24 11:45:35
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100121287099
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew