Energy Performance Certificate

Squirrels Leap, Burton, LN1 2RD

EPC Report

Energy rating

Current: 21 F | Potential: 57 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 57 D Potential: 57 D

Environmental impact (CO₂)

Current: 24 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 54 Potential: 54
Field Value
LMK KEY 0320-2250-0010-2729-3905
ADDRESS1 Squirrels Leap
ADDRESS2 Burton
ADDRESS3
POSTCODE LN1 2RD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 57
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2021-09-20
LOCAL AUTHORITY E07000142
CONSTITUENCY E14001243
COUNTY
LODGEMENT DATE 2021-09-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 410
ENERGY CONSUMPTION POTENTIAL 182
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 106
CO2 EMISSIONS POTENTIAL 5.0
LIGHTING COST CURRENT 142
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 1539
HEATING COST POTENTIAL 1052
HOT WATER COST CURRENT 247
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 98
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 30
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 31
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some multiple glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, LPG
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 31% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Squirrels Leap, Burton
LOCAL AUTHORITY LABEL West Lindsey
CONSTITUENCY LABEL Gainsborough
POSTTOWN LINCOLN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2021-09-20 13:49:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10034683247
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000004
Address display