Energy Performance Certificate

33 Court View, GL10 3PJ

EPC Report

Energy rating

Current: 67 D | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 88 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 90 Potential: 90
Field Value
LMK KEY 0320-2125-4660-2596-7381
ADDRESS1 33 Court View
ADDRESS2
ADDRESS3
POSTCODE GL10 3PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE Flat
BUILT FORM Not Recorded
INSPECTION DATE 2026-06-15
LOCAL AUTHORITY E07000082
CONSTITUENCY E14001529
COUNTY
LODGEMENT DATE 2026-06-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 161
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 0.9
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 47
HEATING COST CURRENT 828
HEATING COST POTENTIAL 639
HOT WATER COST CURRENT 520
HOT WATER COST POTENTIAL 415
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION To unheated space, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33 Court View
LOCAL AUTHORITY LABEL Stroud
CONSTITUENCY LABEL Stroud
POSTTOWN STONEHOUSE
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2026-06-15 18:03:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10001164711
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2026.csv
COUNTRY England
REGION E12000009
Address display
Nation ew