Energy Performance Certificate

16 Cedar Avenue, Haslingden, BB4 5NH

EPC Report

Energy rating

Current: 74 C | Potential: 96 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 96 A Potential: 96 A

Environmental impact (CO₂)

Current: 76 | Potential: 97
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 97 Potential: 97
Field Value
LMK KEY 0320-2015-0240-2804-7301
ADDRESS1 16 Cedar Avenue
ADDRESS2 Haslingden
ADDRESS3
POSTCODE BB4 5NH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 96
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-04-05
LOCAL AUTHORITY E07000125
CONSTITUENCY E14001299
COUNTY
LODGEMENT DATE 2024-04-08
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 97
ENERGY CONSUMPTION CURRENT 195
ENERGY CONSUMPTION POTENTIAL 40
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 863
HEATING COST POTENTIAL 472
HOT WATER COST CURRENT 261
HOT WATER COST POTENTIAL 183
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16 Cedar Avenue, Haslingden
LOCAL AUTHORITY LABEL Rossendale
CONSTITUENCY LABEL Hyndburn
POSTTOWN ROSSENDALE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-04-08 09:11:35
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100010606202
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000002
Address display
Nation ew