Energy Performance Certificate

28, Cunningham Close, Higham Ferrers, NN10 8BS

EPC Report

Energy rating

Current: 65 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 66 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 82 Potential: 82
Field Value
LMK KEY 0319-2885-7197-9494-8141
ADDRESS1 28, Cunningham Close
ADDRESS2 Higham Ferrers
ADDRESS3
POSTCODE NN10 8BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-01-15
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001571
COUNTY
LODGEMENT DATE 2014-01-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 205
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 39
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 630
HEATING COST POTENTIAL 572
HOT WATER COST CURRENT 80
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 78
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Cunningham Close, Higham Ferrers
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Wellingborough and Rushden
POSTTOWN RUSHDEN
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2014-01-15 14:25:09
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100031030459
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew