Energy Performance Certificate

13, Gilroy Way, BR5 4JD

EPC Report

Energy rating

Current: 40 E | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 34 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 72 Potential: 72
Field Value
LMK KEY 0318-9088-7239-3515-3970
ADDRESS1 13, Gilroy Way
ADDRESS2
ADDRESS3
POSTCODE BR5 4JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-01-09
LOCAL AUTHORITY E09000006
CONSTITUENCY E14001417
COUNTY
LODGEMENT DATE 2015-01-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 477
ENERGY CONSUMPTION POTENTIAL 155
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 84
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 990
HEATING COST POTENTIAL 580
HOT WATER COST CURRENT 206
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 70
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13, Gilroy Way
LOCAL AUTHORITY LABEL Bromley
CONSTITUENCY LABEL Orpington
POSTTOWN ORPINGTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-01-16 13:20:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100020459380
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew