Energy Performance Certificate

8, Printers Yard, Uppingham, LE15 9RA

EPC Report

Energy rating

Current: 44 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 38 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 83 Potential: 83
Field Value
LMK KEY 0318-3944-7249-4205-4934
ADDRESS1 8, Printers Yard
ADDRESS2 Uppingham
ADDRESS3
POSTCODE LE15 9RA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2015-11-09
LOCAL AUTHORITY E06000017
CONSTITUENCY E14001458
COUNTY
LODGEMENT DATE 2015-11-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 478
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 84
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 1100
HEATING COST POTENTIAL 492
HOT WATER COST CURRENT 190
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 75
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Printers Yard, Uppingham
LOCAL AUTHORITY LABEL Rutland
CONSTITUENCY LABEL Rutland and Stamford
POSTTOWN OAKHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-11-09 15:33:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100030722490
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew