Energy Performance Certificate

169, Chapel Street, Horningsham, BA12 7LU

EPC Report

Energy rating

Current: 39 E | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 29 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 91 Potential: 91
Field Value
LMK KEY 0315-2823-7721-9601-9455
ADDRESS1 169, Chapel Street
ADDRESS2 Horningsham
ADDRESS3
POSTCODE BA12 7LU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2019-02-07
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001498
COUNTY
LODGEMENT DATE 2019-02-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 319
ENERGY CONSUMPTION POTENTIAL -39
CO2 EMISSIONS CURRENT 8.8
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 962
HEATING COST POTENTIAL 379
HOT WATER COST CURRENT 159
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 98
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 56
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Oil range cooker
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 350 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 56% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 169, Chapel Street, Horningsham
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South West Wiltshire
POSTTOWN WARMINSTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-02-21 13:40:30
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100121337530