9, Mitchell Avenue, Talke, ST7 1JJ

EPC Report

Energy rating

Current: 41 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 38 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 Current: 38 89 Potential: 89
Field Value
LMK KEY 0310-2816-7933-9397-9661
ADDRESS1 9, Mitchell Avenue
ADDRESS2 Talke
ADDRESS3
POSTCODE ST7 1JJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-07-16
LOCAL AUTHORITY E07000195
CONSTITUENCY E14001521
COUNTY
LODGEMENT DATE 2013-07-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 38
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 415
ENERGY CONSUMPTION POTENTIAL 63
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 80
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 906
HEATING COST POTENTIAL 366
HOT WATER COST CURRENT 244
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Mitchell Avenue, Talke
LOCAL AUTHORITY LABEL Newcastle-under-Lyme
CONSTITUENCY LABEL Stoke-on-Trent North
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-07-16 14:54:49
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100031751858
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew