Energy Performance Certificate

28 Abbey Close, UB3 3PJ

EPC Report

Energy rating

Current: 94 A | Potential: 102 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 94 A Current: 94 A 102 A Potential: 102 A

Environmental impact (CO₂)

Current: 91 | Potential: 101
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 101 Potential: 101
Field Value
LMK KEY 0310-2791-5490-2605-7345
ADDRESS1 28 Abbey Close
ADDRESS2
ADDRESS3
POSTCODE UB3 3PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 94
POTENTIAL ENERGY EFFICIENCY 102
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-01-09
LOCAL AUTHORITY E09000017
CONSTITUENCY E14001276
COUNTY
LODGEMENT DATE 2025-01-17
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 91
ENVIRONMENT IMPACT POTENTIAL 101
ENERGY CONSUMPTION CURRENT 50
ENERGY CONSUMPTION POTENTIAL -33
CO2 EMISSIONS CURRENT 0.4
CO2 EMISS CURR PER FLOOR AREA 9
CO2 EMISSIONS POTENTIAL -0.3
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 424
HEATING COST POTENTIAL 322
HOT WATER COST CURRENT 309
HOT WATER COST POTENTIAL 150
TOTAL FLOOR AREA 49
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.23
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28 Abbey Close
LOCAL AUTHORITY LABEL Hillingdon
CONSTITUENCY LABEL Hayes and Harlington
POSTTOWN HAYES
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2025-01-17 13:02:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100021413664
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000007
Address display
Nation ew