Energy Performance Certificate

13 South Close, UB7 9LS

EPC Report

Energy rating

Current: 30 F | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 34 | Potential: 60
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 60 Potential: 60
Field Value
LMK KEY 0310-2630-3410-2124-4251
ADDRESS1 13 South Close
ADDRESS2
ADDRESS3
POSTCODE UB7 9LS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2024-09-20
LOCAL AUTHORITY E09000017
CONSTITUENCY E14001276
COUNTY
LODGEMENT DATE 2024-12-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 60
ENERGY CONSUMPTION CURRENT 432
ENERGY CONSUMPTION POTENTIAL 215
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 119
HEATING COST CURRENT 2854
HEATING COST POTENTIAL 1783
HOT WATER COST CURRENT 351
HOT WATER COST POTENTIAL 202
TOTAL FLOOR AREA 102
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13 South Close
LOCAL AUTHORITY LABEL Hillingdon
CONSTITUENCY LABEL Hayes and Harlington
POSTTOWN WEST DRAYTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2024-12-18 10:44:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100021508064
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000007
Address display
Nation ew