Energy Performance Certificate

FLAT 2, 34 MERRIDALE ROAD, WOLVERHAMPTON, WV3 9SB

EPC Report

Energy rating

Current: 69 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 70 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 81 Potential: 81
Field Value
LMK KEY 0310-2575-9070-2829-6411
ADDRESS1 FLAT 2
ADDRESS2 34 MERRIDALE ROAD
ADDRESS3 WOLVERHAMPTON
POSTCODE WV3 9SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-03-25
LOCAL AUTHORITY E08000031
CONSTITUENCY E14001596
COUNTY
LODGEMENT DATE 2021-03-25
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 277
ENERGY CONSUMPTION POTENTIAL 180
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 350
HEATING COST POTENTIAL 234
HOT WATER COST CURRENT 71
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 38
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.62
FLOOR HEIGHT 2.68
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS FLAT 2, 34 MERRIDALE ROAD, WOLVERHAMPTON
LOCAL AUTHORITY LABEL Wolverhampton
CONSTITUENCY LABEL Wolverhampton West
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-03-25 17:45:21
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100071355395
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew