Energy Performance Certificate

161 Dukes Ride, RG45 6DR

EPC Report

Energy rating

Current: 71 C | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 67 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 Current: 67 85 Potential: 85
Field Value
LMK KEY 0310-2487-7080-2899-2845
ADDRESS1 161 Dukes Ride
ADDRESS2
ADDRESS3
POSTCODE RG45 6DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-08-13
LOCAL AUTHORITY E06000036
CONSTITUENCY E14001117
COUNTY
LODGEMENT DATE 2021-08-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 67
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 183
ENERGY CONSUMPTION POTENTIAL 74
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 101
HEATING COST CURRENT 569
HEATING COST POTENTIAL 420
HOT WATER COST CURRENT 129
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 114
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 161 Dukes Ride
LOCAL AUTHORITY LABEL Bracknell Forest
CONSTITUENCY LABEL Bracknell
POSTTOWN CROWTHORNE
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2021-08-16 11:30:18
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 29
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 100080213847
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew